9.3.10 Frequency (3.10)
Se
ts the country specic settings for radar signals.
Setting
• Mode1
EU, Albania, Andorra, Azerbaijan, Australia, Belarus, Bosnia
and
Herzegovina, Canada, Liechtenstein, Moldavia, Monaco,
Montenegro, New Zealand, Northern Macedonia, Norway,
San Marino, Saudi Arabia, Serbia, Switzerland, Turkey, Uk‐
raine, United Kingdom, USA
• Mode2
Kazakhstan
• Mode3
Brazil, South Korea, Taiwan, Thailand, Japan
• Mode4
India, Malaysia
Default Mode1
9.3.11 Audit trail (3.11)
9.3.11.1 Congur
ation change counter (3.11.1)
Displays number of times device conguration or calibration changed, locally or via engineering
system.
9.3.12 Firmware update (3.12)
9.3.12.1 Data transfer (3.12.1)
Analog output set to 22.8mA during rmware update.
9.3.12.2 Firmware update (3.12.2)
9.4 Communication (4)
The following parameters relate to device Communication.
9.4.1 Polling address (4.1)
Sets poll ID on a HART network.
For point-to-point congurations, the standard address is zero (0). For multidrop
congurations, use a non-zero HART address.
Parameter assignment
9.4Communication (4)
SITRANS LR500 series with mA/HART
Operating Instructions, 03/2024, A5E51099898-AA 145