10.9 Apply
by the user to the robot arm, the limit can be violated. The magnitude of the force increases as the
robot arm comes closer to the limit.
10.7.1 Backdrive
In Freedrive mode, the robot joints can be moved with relatively little force because the brakes are
released. During initialization of the robot arm, minor vibrations may be observed when the robot
brakes are released. In some situations, such as when the robot is close to collision, these tremors
are undesirable and the Backdrive feature can be used to forcefully move specific joints to a desired
position without releasing all brakes in the robot arm.
To enable Backdrive:
1. Press ON to enable power for the joints. The robot state is set to “Idle”. Do not release the
brakes (i.e. do not press START).
2. Press and hold the Freedrive button. The robot state changes to “Backdrive”.
3. Brakes will only be released in the joints to which significant pressure is applied, as long as
the Freedrive button is engaged/pressed. While using Backdrive, the robot feels heavy to move
around.
10.8 Password Lock
All settings on this screen are locked until the correct safety password (see 15.3) is entered in the
white text field at the bottom of the screen and the Unlock button is pressed. The screen can be
locked again by clicking the Lock button. The Safety tab is automatically locked when navigating
away from the safety configuration screen. When the settings are locked, a lock icon is visible next
to the text Safety on the left side of the screen. An unlock icon is shown when the settings are
unlocked.
NOTE:
Note that the robot arm is powered off when the safety Configuration
screen is unlocked.
10.9 Apply
When unlocking the safety configuration, the robot arm will be powered off while changes are
being made. The robot arm cannot be powered on until the changes have been applied or reverted,
and a manual power on is performed from the initialization screen.
Any changes to the safety configuration must be applied or reverted, before navigating away from
the Installation tab. These changes are not in effect until after the Apply button is pressed and
confirmation is performed. Confirmation requires visual inspection of the changes given to the
robot arm. For safety reasons, the information shown is given in SI Units. An example of the
confirmation dialog is shown below.
CB3 II-8 Version 3.10
Copyright © 2009–2019 by Universal Robots A/S. All rights reserved.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Universal Robots UR3/CB3 and is the answer not in the manual?

Universal Robots UR3/CB3 Specifications

General IconGeneral
BrandUniversal Robots
ModelUR3/CB3
CategoryRobotics
LanguageEnglish

Related product manuals