19 Installing and uninstalling the interface
To achieve redundancy of the safety functionality, the controller box knows whether it shall expect
a EUROMAP 67 interface to be present or not. Therefore, the installing and uninstalling procedures
below must be followed precisely.
Please note the orientation of the ribbon cable below.
CAUTION:
1. Do not plug/unplug the ribbon cable when the controller box is
powered on.
2. The ground (earth) connection shall be screwed on when plug-
ging/unplugging the ribbon cable.
3. Never power on the control box without the ground (earth) con-
nection.
19.1 Installing
The interface can be placed at the bottom or in the left side of the controller box, see pictures below
and follow the procedure. It is not allowed to install the interface in any other way.
1. Power down the controller box.
The green light of the power button of the teach pendant must be off.
2. Mount the interface.
Use 1 M6 nut to screw on the ground connector.
Use 4 M4×8mm screws to screw on the interface.
Use 4 M4×8mm screws to cover the empty holes.
Figure 19.1: Ribbon cable connection
Version 3.10
Copyright © 2009–2019 by Universal Robots A/S. All rights reserved.
III-23 CB3

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Universal Robots UR3/CB3 and is the answer not in the manual?

Universal Robots UR3/CB3 Specifications

General IconGeneral
BrandUniversal Robots
ModelUR3/CB3
CategoryRobotics
LanguageEnglish

Related product manuals