If the position of the sample output is correct, a line is printed at a position 10 mm
from the edge of the paper. If the position of the line on the sample output is
misaligned, make adjustments accordingly.
Note
Two lines are printed on the image of side 1 and one line is printed on the image of
side 2 of the sample that is printed with Sample Printout to indicate the paper feed
direction.
13. Press Save.
14. Check the sample output, and adjust the position if misalignment has occurred.
15. After you finish making adjustments, print another output sample by pressing the
Sample Printout and verify the adjustment results.
16. Make adjustments again if necessary and press Save.
17. Press Save.
18. Press Close.
19. Select the tray to assign the set type (the tray in which you loaded the paper in Step
1), and press Change Settings.
20. Select the adjusted type, and press Save.
Adjusting Values
Adjust the size (scale) of the image with respect to the lead edge direction and the side
edge direction according to the paper feed direction by 0.025% increments for each of
sides (side 1 and 2). You can adjust up to 0.400%. Specify a positive value when you
want to increase the scale, and a negative value when you want to reduce it.
1. Check the sample output, and measure the scale offset amount that occurred.
Paper feed direction: X direction scale
X direction scale offset amount = image reference length in the X direction - image
actual measurement length in the X direction
Vertical direction in relation to the paper feed direction: Y direction scale
Y direction scale offset amount = image reference length in the Y direction - image
actual measurement length in the Y direction
The reference lengths for a sample output of A3 or A4 size printed with Sample
Printout are as follows.
Image Reference Length in the Y Direc-
tion
Image Reference Length in the X
Direction
Paper Size
277 mm400 mmA3
277 mm190 mmA4
2. Select X% or Y%, then press Change Settings.
3. Enter the offset amount of the X direction scale you measured in Step 1 for Side 1
and Side 2 of X%.
10-23Xerox
®
D95/D110/D125/D136 Copier/Printer
System Administration Guide
System Settings