© Cesab 5 – 5 T Code(s): 841, 842, 843
Repair manual: Parameters Model(s): S210, S212, S212S, S212L, S214, S214L, S220D
Publication Number: 7588857-040 Date: 2018-05-01 Applies from serial number: 6384351-
Parameters 6 and 7 – Maximum travel speed
These two parameters are used to limit the maximum travel speed for the
logged-in operator profile.
The maximum travel speed can also be limited by factory parameter #1044
and it is always the lowest speed for a parameter that is the limiting one.
# 6 - Maximum speed
Determines the maximum travel speed.
# 7 - Maximum speed, forks above 1.8m
Adjusts the truck maximum speed when the forks are above 1.8 m, Is set as
a % of parameter 203.
Par. Description Min.
Defa
ult
Max.
Incre
ment
Unit
6 Maximum speed 30 100 100 5 %
7
Maximum speed, forks above
1.8 m
30 100 100 5 %