© Cesab 5 – 41 T Code(s): 841, 842, 843
Repair manual: Parameters Model(s): S210, S212, S212S, S212L, S214, S214L, S220D
Publication Number: 7588857-040 Date: 2018-05-01 Applies from serial number: 6384351-
Parameter 1044 - Master maximum speed
#1044 - Master maximum speed
Sets the maximum speed for the application. The speed can never exceed
the value of this parameter, regardless of the settings of the other
parameters.
Parameter 1045 - Type of battery in the truck
# 1045 - Type of battery in the truck
Specifies the type of battery found in the application.
Par. Description Min.
Defa
ult
Max.
Incre
ment
Unit
1044 Master maximum speed 0.5 6.0 6.0 0.5 km/h
Par. Description Min.
Defa
ult
Max.
Incre
ment
Unit
1045 Type of battery in the truck 0 0 1 1
Value Function
0 Lead/acid battery
1 Li-ion battery
https://www.forkliftpdfmanuals.com/