© Cesab 5 – 22 T Code(s): 841, 842, 843
Repair manual: Parameters Model(s): S210, S212, S212S, S212L, S214, S214L, S220D
Publication Number: 7588857-040 Date: 2018-05-01 Applies from serial number: 6384351-
5.4.1 Description
Parameter 301 – Ramping value for lowering stop
Applies to S208L, 210, 212S, 212L, 212, 214L, 214, 220D
# Parameter 301 – Ramping value for lowering stop
Determines the closing ramp of the proportional valve.
Parameter 302 - Fork, lowering speed
Applies to S208L, 210, 212S, 212L, 212, 214L, 214, 220D
# Parameter 302 - Fork, lowering speed
Determines the maximum lowering speed of the forks. This parameter can be
adjusted manually or can be set by using the calibration function
Parameter 303 - EVP start mode
Applies to S208L, 210, 212S, 212L, 212, 214L, 214, 220D
# Parameter 303 - EVP start mode
Determines the start position of the proportional valve. This parameter can be
adjusted manually or can be set by using the calibration function
Par. Description Min.
Defa
ult
Max.
Incre
ment
Unit
301 Lowering stop ramp 3 7 20 1
Par. Description Min.
Defa
ult
Max.
Incre
ment
Unit
302 Fork lowering speed 70 190 255 5
Par. Description Min.
Defa
ult
Max.
Incre
ment
Unit
303 EVP startup mode 30 90 150 5
https://www.forkliftpdfmanuals.com/