© Cesab 5 – 45 T Code(s): 841, 842, 843
Repair manual: Parameters Model(s): S210, S212, S212S, S212L, S214, S214L, S220D
Publication Number: 7588857-040 Date: 2018-05-01 Applies from serial number: 6384351-
Parameter 1118 - Hardware version
#1118 - Hardware version
Determines the [T1] ACT version on the truck
* Matrix for hardware/software compatibility
See the matrix below for the correct setting of factory parameter 1118. The
setting depends on which version of motor control is installed on the truck.
• Value 0 = 1.5 kHz (default value)
• Value 1 = 8 kHz
— Slut på avsnittet —
Par. Description Min.
Defa
ult
Max.
Incre
ment
Unit
1118 Hardware version 0 1 1 1
Value Function
0 Before 2010-03-22
1 After 2010-03-22
Motor controller Factory parameter 1118
Value = 0 Value = 1
243428-001/-002
246889-001/-002
246890-001/-002
OK Not permitted
7513528-001/-newer
7513526-001/-newer
7513527-001/-newer
Not
recommended
OK