© Cesab 7 – 3 T Code(s): 841, 842, 843
Repair manual: Maintenance Model(s): S210, S212, S212S, S212L, S214, S214L, S220D
Publication Number: 7588857-040 Date: 2018-05-01 Applies from serial number: 6384351-
7.2.7 Electric components
• Clean electric motors using vacuum cleaner or a rag.
• Clean electric panels, logic cards, contactors, connectors, magnetic
valves, etc. with a rag moistened with water and a suitable detergent.
Note:
Risk of short circuiting.
Risk of damage to electrical components.
Do not break the warranty seals on the electronic circuit boards.
7.3 Maintenance schedule
Service maintenance should be performed in intervals of 750 operating hours
or every 12 months, whichever occurs first.
The order in the maintenance schedule is not optimal for the working order; it
is simply sorted according to the C codes.
For details on oil and grease specifications, see chapter 23.2