© Cesab 5 – 6 T Code(s): 841, 842, 843
Repair manual: Parameters Model(s): S210, S212, S212S, S212L, S214, S214L, S220D
Publication Number: 7588857-040 Date: 2018-05-01 Applies from serial number: 6384351-
5.2 General service parameters
Before any service parameter can be changed, the CAN service key must be
connected to the contact [X41].
5.2.1 Overview
Note:
Changing specific truck parameters changes the truck's driving properties.
Do not change any parameter values without the necessary know-how.
Par. Description
101 Service intervals
102 Operator access
103 Start-up - alternative
104 Automatic logout/min
105 Collision sensor X level
106 Collision sensor Y level
107 Battery adjustment, Ah
109 Battery type, built-in charger
110 Battery size, built-in charger
111 Reset following a collision
112 Clear application data