© Cesab 6 – 8 T Code(s): 841, 842, 843
Repair manual: Installation and commissioning Model(s): S210, S212, S212S, S212L, S214, S214L, S220D
Publication Number: 7588857-040 Date: 2018-05-01 Applies from serial number: 6384351-
6.7 Setting parameters
This chapter covers only those parameters that need to be set upon
commissioning of the truck and which require detailed descriptions. Fore
more information on the parameters, please refer to the Parameters chapter.
Check to make sure all parameters are set to the desired values in terms of
• maximum speed, operator parameter - Page 5–3
• acceleration, operator parameters - Page 5–3
• deceleration, operator parameters - Page 5–3
• collision sensor (option) - Page 5–9
• battery - Page 5–10
• battery charger (option) - Page 5–15Page 5–42
Note:
When checking or setting parameters, be sure to keep written records, e.g. in
a truck report, of the truck's specific parameter values. This separate
information on truck-specific parameters can come in handy, e.g. in case of
downtime, since the information is not available elsewhere.