Page #544 background imageLoading...
Page #544 background image
2-512
Catalyst 3560 Switch Command Reference
78-16405-05
Chapter 2 Catalyst 3560 Switch Cisco IOS Commands
show power inline
show power inline
Use the show power inline user EXEC command to display the Power over Ethernet (PoE) status for the
specified PoE port or for all PoE ports.
show power inline [interface-id | consumption default] [ | {begin | exclude | include} expression]
Syntax Description
Command Modes User EXEC
Command History
Usage Guidelines Expressions are case sensitive. For example, if you enter | exclude output, the lines that contain output
do not appear, but the lines that contain Output appear.
Examples This is an example of output from the show power inline command. In the display, port 2 is configured
as static; power has been pre-allocated to this port, but no powered device is connected. Port 6 is a static
port in the power-deny state because its maximum wattage is configured for 10 W. The connected
powered device has a reported class maximum wattage for a Class 0 or Class 3 device.
Switch> show power inline
Available:370.0(w) Used:80.6(w) Remaining:289.4(w)
Interface Admin Oper Power Device Class Max
(Watts)
--------- ------ ---------- ------- ------------------- ----- ----
Fa0/1 auto on 6.3 IP Phone 7910 n/a 15.4
Fa0/2 static off 15.4 n/a n/a 15.4
Fa0/3 auto on 6.3 IP Phone 7910 n/a 15.4
Fa0/4 auto on 6.3 IP Phone 7960 2 15.4
Fa0/5 static on 15.4 IP Phone 7960 2 15.4
Fa0/6 static power-deny 10.0 n/a n/a 10.0
Fa0/7 auto on 6.3 IP Phone 7910 n/a 15.4
<output truncated>
This is an example of output from the show power inline command on a port:
Switch> show power inline fastethernet0/1
interface-id (Optional) Display PoE-related power management information for the
specified interface.
consumption default (Optional) Display the power allocated to devices connected to PoE ports.
| begin (Optional) Display begins with the line that matches the expression.
| exclude (Optional) Display excludes lines that match the expression.
| include (Optional) Display includes lines that match the specified expression.
expression Expression in the output to use as a reference point.
Release Modification
12.1(19)EA1 This command was introduced.
12.2(25)SEC The consumption default keywords were added.