DVP15MC11T Operation Manual
3.1 Function Specifications
3.1.1 Specifications
Item Specification
Programming
Program
capacity
Quantity
POU
definitions
1024
capacity for
Non-retained Size 20M
G code
One single G code
program
Size 256K
Motion
control
Number of
controlled
axes
Max. number of axes for
single-axis control
Real axis: 1~24, Virtual axis: 1~32.
The virtual axis number is different
from the real axis number.
Max. number of axes for linear
interpolation
8
Max. number of axes for circular
interpolation
3
Size Quantity 64
Key points of one
single cam
Quantity 2048
Built-in ports of DVP15MC11T
CAN 2
One CAN port supports the
standard CANopen protocol and the
other CAN port is used in Motion.
Two independent Ethernet ports
Used as a master or slave
Used as a master or slave
2
Builds an encoder axis. Z signal can
trigger an interrupt program.
encoder
1 Builds an encoder axis
Input points Quantity
16 points (External interrupt trigger
is supported.)
1
Slim-series left-side extension
module
Right-side
extension port
1 Slim series special module
Left-side and
right-side
extension
extension
modules
Quantity
8 pieces of Slim series left-side
extension modules
Right-side
extension
Special modules Quantity
8 pieces of Slim series special
modules
Digital modules
240 input points and 240 output
points
3-2