EasyManuals Logo
Home>Delta Electronics>Controller>DVP15MC11T

Delta Electronics DVP15MC11T User Manual

Delta Electronics DVP15MC11T
601 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #207 background imageLoading...
Page #207 background image
DVP15MC11T Operation Manual
_8
8.11.3 SEL
FB/FC
Explanation
Applicable
model
FC
SEL is used for selecting one of two variables or constants and the selected
value is output to Out.
DVP15MC11T
Parameters
Parameter
name
Meaning
Input/
Output
Description Valid range
G Gate Input
In0 is selected when G is
FALSE;
In1 is selected when G is
TRUE.
Depends on the data type of the
variable that the input parameter is
connected to.
In0 and In1
Selections Input Data to be selected
Depends on the data type of the
variable that the input parameter is
connected to.
Out
Selection
result
Output Selection result
Depends on the data type of the
variable that the output parameter is
connected to.
Boolean
Bit string Integer
Real
number
Time, date
String
BOOL
BYTE
WORD
DWORD
LWORD
USINT
UINT
UDINT
ULINT
SINT
INT
DINT
LINT
REAL
LREAL
TIME
DATE
TOD
DT
STRING
G
In0
and
In1
Out
Note:
The symbol indicates that the parameter is allowed to connect to the variable or constant of the data type.
Function Explanation
According to the selection condition G, the SEL instruction selects one of two variables or constants
and the selection result is output to Out.
SEL
EN ENO
G Out
In1
In0
8-136

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Delta Electronics DVP15MC11T and is the answer not in the manual?

Delta Electronics DVP15MC11T Specifications

General IconGeneral
BrandDelta Electronics
ModelDVP15MC11T
CategoryController
LanguageEnglish

Related product manuals