EasyManuals Logo
Home>Delta Electronics>Controller>DVP15MC11T

Delta Electronics DVP15MC11T User Manual

Delta Electronics DVP15MC11T
601 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #497 background imageLoading...
Page #497 background image
DVP15MC11T Operation Manual
11
1
The position where the engagement starts is reached as the master axis passes 100 at t3. The
slave axis starts to perform the engagement action according to StartMode at t3. The
synchronization is achieved at t4 and the InSync output parameter (CamIn1_InSync) changes
from FALSE to TRUE.
During the synchronous cam motion in which the slave axis follows the motion of the master
axis, by executing the MC_CamOut instruction, the cam relationship is disconnected at t6.
After the MC_CamOut instruction is executed, the slave axis will keep moving at the speed it
has when the slave axis is disconnected from the cam relationship.
11-174

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Delta Electronics DVP15MC11T and is the answer not in the manual?

Delta Electronics DVP15MC11T Specifications

General IconGeneral
BrandDelta Electronics
ModelDVP15MC11T
CategoryController
LanguageEnglish

Related product manuals