Separate ground cable
F-8
F.6.2 Ground cable - connection
Mount the ground cable close to and parallel to the shielded coax cable thus minimizing
ground loop problems. If possible, route the coax cable and the ground cable in metal
conduits bonded to the hull or within a mast (depending on the actual installation).
The ground cable must be connected at one of the mounting/grounding bolts on the ADU.
Use bolts and washers of stainless steel and seal the joint with protective coating to avoid
corrosion. If the ADU is to be isolated from the mounting base, shoulder bushings and
washers must be used — see figure F-7, Isolation of the ADU from the mounting base on
page F-8.
At the other end, connect the ground cable as described in To ground the ACU on page F-
2.
F.6.3 Isolation of the ADU from the mounting base
In cases where the ADU is to be isolated from the mounting base, shoulder bushings and
washers (accessories) must be used as illustrated below. Please note that the isolation has
to be implemented on all four mounting bolts (including the bolt securing the ground
cable).
Figure F-7: Isolation of the ADU from the mounting base
Isolating shoulder bush
Isolating washer
Plain washer
Spring washer
(stainless steel)
(stainless steel)