11 – 138 HEIDENHAIN Service Manual iTNC 530
11.5 Overviews
The following tables are excerpts from the iTNC 530 Technical Manual of May 2009.
Overview of
markers
A list of PLC operands with brief description in English and German (GLB_NC_de.DEF,
GLB_NC_en.DEF) is available on the control under PLC:\JH\.
Spindle
Thread cutting
Coolant status
Touch probe
Operand Description Set Reset As of SW vers.
M 1900 -
1999
Decoded M function if M4571 is set NC NC
Operand Description Set Reset As of SW vers.
M 4000 Spindle in position NC NC
M 4001 Nominal speed command signal of the spindle not in the ramp NC NC
M 4002 Nominal speed value = 0 NC NC
M 4003 Nominal speed value output analog or digital (MP3010 = 3 to 8) NC NC
M 4004 Impermissible speed was programmed NC NC
M 4005 Status display and nominal speed value output for M03 PLC PLC
M 4006 Status display and nominal speed value output for M04 PLC PLC
M 4007 Status display M05 and spindle stop PLC PLC
M 4008 Disable speed output for spindle PLC PLC
M 4009 Counterclockwise spindle rotation (for gear change) PLC PLC
M 4010 Clockwise spindle rotation (for gear change) PLC PLC
M 4011 Activate rotational speed MP3520.0 and rotational direction M4013 PLC PLC
M 4012 Open the spindle control loop PLC PLC
M 4013 Direction for spindle orientation from a standstill (M03 = 0; M04 = 1) PLC PLC
M 4014 Reverse the direction of spindle rotation PLC PLC
M 4015 Renewed evaluation of the spindle reference mark PLC NC
M 4016 Cycle 13 is executed NC PLC
M 4017 Servo-controlled spindle in motion NC NC
M 4018 Reference mark for spindle not yet traversed NC NC
M 4019 Reversing the counting direction of position encoder on the spindle PLC PLC
Operand Description Set Reset As of SW vers.
M 4030 Cycle 2 or Cycle 17 active NC NC
M 4031 Cycle 17 or cycle 18 active NC NC
Operand Description Set Reset As of SW vers.
M 4040 Status display M07, M08, and M09 highlighted PLC PLC
M 4041 Status display M07, M08, M09, MK PLC PLC
M 4042 Status display M07, M08, M09, MK PLC PLC
Operand Description Set Reset As of SW vers.
M 4050 Touch probe not ready, ready signal is missing NC NC
M 4051 Stylus deflected before start of probing cycle NC NC
M 4052 Stylus is deflected, probing process is completed NC PLC