15.4 Execution as of NC Software 34049x-02 (Single-Processor Version)
Unzipping the
ZIP File
The provided ZIP file (e.g., 34049004sp6.zip) has still to be unzipped on a data medium (PC/
laptop/USB stick)!
A folder with the number of the NC software (e.g., 34049004) is created.
This folder contains a subdirectory (e.g., 340490_004_SP6), of the following files:
setup.elf (previously setup.omf)
setup.ini (optional)
setup.zip
Access to the
service pack files
via the customer
network
If the control is connected to the company network and the service pack files were filed on a
released folder of the network, you have access to these data. --> If necessary, ask the system
administrator.
Otherwise, you can also use a USB stick as data medium (or transfer the service pack from your
service laptop to the control).
Loading the
service pack
8 Connect the USB stick to X141 or X142 (USB interfaces of the iTNC 530).
8 Select the Programming and Editing operating mode.
8 If open: Close the program management by pressing the END button.
8 Press the MOD key.
8 Enter the code number SETUP. --> A pop-up window appears.
8 In the upper part of the window, set the cursor to the USB data medium (or to the partition of
the control's hard disk where you have transferred the service pack with TNCremoNT).
8 Now set the cursor to the folder with the designation of the NC software + service pack
(e.g., 340490_004_SP6).
8 Press ENT. --> The file setup.elf (previously setup.omf) is shown in the lower part of the
window.
Note
When connecting, USB memory devices that use the file system VFAT or ISO 9660
(not NTFS, or similar), are recognized automatically as of NC software version 34049x-02
with feature content level L2.
If level 2 is not set, you can transfer the service pack with TNCremoNT to the control's hard
disk See “Transferring files service packs from the laptop to the control” on page 15 – 221.
Note
Pressing the MOD key while the program manager is open calls the interface settings.
Note
With the +/- key you may open and close the directory trees.

Table of Contents

Other manuals for HEIDENHAIN ITNC 530

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HEIDENHAIN ITNC 530 and is the answer not in the manual?

HEIDENHAIN ITNC 530 Specifications

General IconGeneral
BrandHEIDENHAIN
ModelITNC 530
CategoryControl Systems
LanguageEnglish

Related product manuals