July 2010 30 – 609
30.4.8 Configuration of the Data Interface
MP Function and input SW version
and
behavior
MP5000 Disable data interfaces
Input: 0: No interface disabled
1: RS-232-C/V.24 interface disabled
2: RS-422/V.11 interface disabled
3: RS-232-C/V.24 and RS-422/V.11 interfaces disabled
PLC
RUN
MP5020 Configuration of the data interface
Format: %xxxxxxxx
Input: Bit 0 –
0: 7 data bits
1: 8 data bits
Bit 1 –
0 : Any BCC character
1 : BCC not control character
Bit 2 –
0: Transmission stop by RTS not active
1: Active
Bit 3 –
0: Transmission stop by DC3 not active
1: Active
Bit 4 –
0: Character parity even
1: Odd
Bit 5 –
0: Character parity not desired
1: Desired
Bit 6 = 0, Bit 7 = 0: 1.5 stop bits
Bit 6 = 1, Bit 7 = 0: 2 stop bits
Bit 6 = 0, Bit 7 = 1: 1 stop bit
Bit 6 = 1, Bit 7 = 1: 1 stop bit
Bit 8, 9 - reserved
Bit 10 –
Check for missing connection
0: Active
1: Not active
PLC
RUN
CN123
340 490-05
MP5020.0 Operating mode EXT1
MP5020.1 Operating mode EXT2
MP5020.2 Operating mode EXT3 (PLC)
MP5020.3 Operating mode EXT4 (PLC)
MP5030 Data transmission protocol
Input: 0 = Standard data transfer protocol
1 = Blockwise transfer
2 = Without protocol (only for MP5030.2)
PLC
RUN
CN123
MP5030.0 Operating mode EXT1
MP5030.1 Operating mode EXT2
MP5030.2 Operating mode EXT3 (PLC)
MP5030.3 Operating mode EXT4 (PLC)