July 2010 22 – 367
22.5 Checking the Potentiometers
Potentiometer
values in the
PLC-TABLE
You can use the table for the PLC words to find out, whether the control receives the
potentiometer signal.
The potentiometer setting is shown in the following PLC words:
W492 (=S override)
W494 (= F override)
Proceed as follows:
8 Switch on the machine.
8 Press the EMERGENCY STOP button.
8 Call the table with the PLC words. --> See “The TABLE function” on page 11 – 119.
8 Place the cursor on W492 or W494 (e.g., GOTO 492).
8 Select the decimal display (soft key).
8 Turn the potentiometer to be examined.
8 Check if the display can be changed from 0 to 15000 (with nonlinear characteristic curve) or
0 to 150 (with linear characteristic curve).
The characteristic curve is defined in MP 7620 bit 3.
Potentiometer
values in
the integrated
oscilloscope
With the integrated oscilloscope you can record the states of PLC words as well.
The advantage of this method is that possible wiper interruptions of the potentiometers can be
recognized better than in the PLC TABLE.
Proceed as follows:
8 Switch on the machine.
8 Press the EMERGENCY STOP key.
8 Call the oscilloscope. --> See “Integrated Oscilloscope” on page 10 – 99.
8 Make the following settings:
8 Start the recording.
8 Turn the potentiometer to be examined.
8 Stop recording and adjust the signals.

Table of Contents

Other manuals for HEIDENHAIN ITNC 530

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HEIDENHAIN ITNC 530 and is the answer not in the manual?

HEIDENHAIN ITNC 530 Specifications

General IconGeneral
BrandHEIDENHAIN
ModelITNC 530
CategoryControl Systems
LanguageEnglish

Related product manuals