EasyManuals Logo
Home>HEIDENHAIN>Control Systems>ITNC 530

HEIDENHAIN ITNC 530 Service Manual

HEIDENHAIN ITNC 530
696 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #492 background imageLoading...
Page #492 background image
27 – 492 HEIDENHAIN Service Manual iTNC 530
27.3.3 UV 106 (B) power supply unit
Connection
overview
UV 106 (B)
X31:
Power supply of the
UV 106 (B)
Supply voltage: 400 V ± 10%
Pin layout:
Equipment ground (YL/GY) ≥ 10 mm
2
Connecting terminal Pin layout
U Phase 1 / 400 Vac ±10% / 50 Hz to 60 Hz
V Phase 2 / 400 Vac ±10% / 50 Hz to 60 Hz
Protective ground (YL/GN),
≥ 10 mm
2
Connecting leads
Wire cross section: 1.5 mm
2
(AWG 16)
Tightening torque:
for the connecting terminals
0.7 Nm (6.5 to 7 lb-ibn)
Grounding terminal:
≥ 10 mm
2
(AWG 6)
Strain relief:
Ensure that the connecting cables are not subject to excessive strain.