July 2010 12 – 153
12.4 Test of Hard Disk
No communication
with the hard disk
When the control is started and there is no communication with the hard disk, normally the
following error message is displayed:
Boot: Giving up
Reason is: Load processes failed
or
No bootable device available
8 Check, whether the memory card is firmly in the slot, or check the hard disk on a functioning
iTNC 530 (if available).
At present no further tests are possible in the field!
Communication
with the hard disk
If data are still transferred to the hard disk, some tests could be carried out in the field. --> See
following instructions.
Additional and more comprehensive tests can only be performed at HEIDENHAIN
agencies!
Caution
Do not use your own hard-disk test or repair programs!
Data recovery at HEIDENHAIN or a specialized company could thereby become more
difficult or even impossible.