30.4.9 3-D touch probe
MP Function and input SW version
and
behavior
MP6010 Selection of the touch probe
Input: 0: Touch probe with cable transmission (TS 120, TS 220)
1: Touch probe with infrared transmission (TS 632)
2: Touch probe with infrared transmission (TS 440, TS 640)
3: TS 444 touch probe, battery free
PLC
CN123
340 490-04
MP6120 Probing feed rate (triggering touch probe)
Input: 1 to 10 000 [mm/min]
PLC
RUN
CN123
340 490-05
MP6130 Maximum measuring range
Input: 0.001 to 99 999.9999 [mm]
PLC
RUN
CN123
MP6140 Setup clearance above measuring point
Input: 0.001 to 99 999.9999 [mm]
PLC
RUN
CN123
MP6150 Rapid traverse in probing cycle
Input: 10 to 20 000 [mm/min]
PLC
RUN
CN123
MP6151 Pre-positioning in probing cycle with rapid traverse
Input: 0: Pre-position with speed from MP6150
1: Pre-positioning at rapid traverse
340 490-02
PLC
RUN
CN123
MP6160 M function for probing from opposite directions
Input: –1: Spindle orientation directly by NC
0: Function inactive
1 to 999: Number of the M function for spindle orientation through PLC
PLC
RUN
CN123
MP6161 M function for orienting the touch probe before every measuring process
Input: –1: Spindle orientation directly by the NC
0: Function inactive
1 to 999: Number of the M function
PLC
RUN
CN123
MP6162 Orientation angle
Input: 0 to 359.9999 [°]
PLC
RUN
CN123
MP6163 Minimum difference between the current spindle angle and MP6162 before executing
an oriented spindle stop
Input: 0 to 3.0000 [°]
PLC
RUN
CN123
MP6165 Orient the probe before approaching with Cycle 0 or 1, or with manual probing
Input: 0: Probe is not oriented before each probing
1: Probe is oriented and always deflected in the same direction
PLC
RUN
CN123
MP6166 Probing direction of the touch probe with consideration of an active basic rotation (only
manual measuring cycles)
Input: 0: Inactive
1: Active
PLC
RUN
CN123

Table of Contents

Other manuals for HEIDENHAIN ITNC 530