30 – 608 HEIDENHAIN Service Manual iTNC 530
MP4131.0
MP4131.1
MP4131.2-5
Activation criterion for fast PLC input for switching off the monitoring functions
Reserved
Activation criterion for fast PLC inputs
Input: 0: Activation at low level
1: Activation at high level
MP4210.0-47 Setting a number in the PLC (D768 to D956)
Input: -99 999.9999 to +99 999.9999
MP4220.0-4 Setting a number in the PLC (W960 to W968)
Input: 10 to 30 000
MP4230.0-31 Setting a number in the PLC (Module 9032)
The number of indexes can be increased via an entry in OEM.SYS.
Input: -99 999.9999 to +99 999.9999
MP4231.0-31 Setting a number in the PLC (Module 9032)
Input: -99 999.9999 to +99 999.9999
MP4310.0-9 General parameters in the PLC (W976 to W994, M4300 to M4459)
Format: Number, $xxxx [Hex], %xxxxxxxxxxxxxxxx [Bin]
Input: 0 to 65535
340 490-03
MP Function and input SW version
and
behavior