18 – 310 HEIDENHAIN Service Manual iTNC 530
IK 215 Use the IK 215 interface card for inspecting and testing an EnDat encoder. --> See “IK 215
Adjusting and Testing Package” on page 29 – 570
DANGER
If the IK 215 is connected in the signal path between the encoder and the control
component:
Do not change the settings of the IK 215 (e.g., parameters, encoder voltages) and do not
switch it off while the machine tool is operating.
This could lead to damage or injury to the machine or persons!
Read the operating instructions of the IK 215 in detail, before you use the unit.
Note
A detailed explanation of the device is part of our training courses on measuring systems.
We recommend that you participate in a HEIDENHAIN service training course so that you
can use the IK 215 correctly and effectively.
Contact HEIDENHAIN Traunreut or your regional agency.

Table of Contents

Other manuals for HEIDENHAIN ITNC 530

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HEIDENHAIN ITNC 530 and is the answer not in the manual?

HEIDENHAIN ITNC 530 Specifications

General IconGeneral
Control TypeCNC
Look-aheadYes
Spindle controlYes
Touch probe cyclesYes
Operating voltage24 V DC
ProgrammingConversational and DIN/ISO programming
InterpolationLinear, Circular, Helical
Data InterfaceEthernet, USB, RS-232
Memory1 GB
Programming LanguageHEIDENHAIN plain language
Operating ModesManual, Automatic, MDA
Software OptionsVarious software options available

Related product manuals