Operation - System Configuration
Part No.: 4418309_Rev09 Fusion4 MSC-L
Honeywell Installation & Operation Manual 5 - 133
[Workflow Selection]
This configuration selects which
workflow is started when the device is
powered up. The MSC-L can support
two independent workflow
configurations (Default and Custom).
One of these two configurations
(Default) is programmed in the factory
and contains sufficient functionality to
perform compartment loading without
any TAS interaction. The MSC-L
prompting configuration settings enable
and disable certain specific prompts
used in this default workflow. The
custom workflow can be initialized by
first changing the workflow selection
setting to custom and then applying a
custom workflow XML file through the
LAD. The device must be restarted for
this workflow to take effect. After
changing the workflow selection
setting, the device should always be
reset to restart the desired workflow.
Refer to 5.13.1.8.1.1 to run local and
remote loading in MSC-L for 1010BJ
and 1010RT emulation.
<Default> (default)
<Custom>
[TAS timeout]
With this entity you can select the TAS
request timeout duration.
<10s> (default)
[Workflow Mode]
Select this entity to operate MSC-L in
either standalone or operate with TAS
<Local>
MSC-L device will operate in
standalone mode
<Remote with Local fallback>
MSC-L will be controlled by TAS, and in
case of communication failure, it will
switch back to stand alone operation
<Remote only>
MSC-L will always be controlled by
TAS
When using emulation type as
Accuload, make sure that the
[Workflow Mode] is <Remote only>.
<Local> (default)
<Remote with Local fallback>
<Remote>
[Use RIT Panel]
With this entity you can enable or
disable the RIT panel
<Enable>
<Disable>(default)
[Allow Reset Alarms by SL1
User]
With this entity, you can allow SL1 user
to reset all alarms except those at
device level.
<Enable>
<Disable> (default)
Entity Description Value range

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honeywell Fusion4 MSC-L and is the answer not in the manual?

Honeywell Fusion4 MSC-L Specifications

General IconGeneral
BrandHoneywell
ModelFusion4 MSC-L
CategoryDesktop
LanguageEnglish

Related product manuals