Section 3: Instrument description Series 3700A System Switch/Multimeter Reference Manual
3-10 3700AS-901-01 Rev. D/June 2018
The following table contains descriptions of the main menu options and cross-references to related
information. To access a menu option, press the MENU key, turn the navigation wheel to move the
cursor to select an item, and press the navigation wheel .
For more information, see:
Saves and recalls user's scripts
Manage scripts (on page 10-3)
Automatically generates a user script that is saved to a
script with a name that you define
Create a configuration script (on page 3-
35)
Loads scripts into nonvolatile memory
Saves and recalls user and factory setup options
Saved setups (on page 3-30)
Recalls user setup options
Sets the configuration used during startup
Resets the instrument, restores factory default settings,
removes channel patterns, reading buffers, and DMM
configurations, and opens channels and backplane relays
Configures the GPIB interface options
Remote communications interfaces (on
page 2-6)
Configures the address for the GPIB interface
Enables and disables the GPIB interface
Configures the local area network (LAN)
LAN concepts and settings (on page A-1)
Displays LAN connection status
Configures the LAN IP address and gateway
Applies changes made using the LAN CONFIG menu
Restores the default settings
Enables and disables the LAN interface
Configures the instrument in a TSP-Link
®
network
TSP-Link system expansion interface (on
page 10-53, on page 10-52)
Selects the instrument node identifier
Resets the TSP-Link network
Upgrades the firmware from a USB flash drive
Upgrading the firmware (on page 7-5)
Sets the model number that is reported when the model
number is queried
Report the model as a 3706A
Report the model as a 3706
Select the type of close and open duration
Working with channels (on page 5-13)
Select the connection rule when opening and closing
channels
Determines if channels are closed sequentially
Accesses display functions
Front panel tests (on page 7-3)
Digital I/O (on page 2-28)
Selects the digital I/O values
Write-protects specific digital I/O lines
Enable or disable key clicks
Enable or disable the beeper and key clicks
Displays the system information
Displays the version of firmware installed
Displays the serial number of the instrument
Displays memory usage in percentage
Displays the last calibration date and number of times the
instrument has been adjusted
* TSPLINK is not available on the Models 2604A, 2614A, and 2634A.
** DIGIO is not available on the Models 2604A, 2614A, and 2634A.