Section 9: Introduction to TSP operation Series 3700A System Switch/Multimeter Reference Manual
9-24 3700AS-901-01 Rev. D/June 2018
channel.trigger[N].get() (on page 11-102)
channel.trigger[N].set() (on page 11-103)
channel.trigger[N].wait() (on page 11-104)
channel.write() (on page 11-105)
Data queue
Use the data queue commands to:
• Share data between test scripts running in parallel
• Access data from a remote group or a local node on a TSP-Link
®
network at any time
The data queue in the Test Script Processor (TSP
®
) scripting engine is first-in, first-out (FIFO).
You can access data from the data queue even if a remote group or a node has overlapped
operations in process.
dataqueue.add() (on page 11-110)
dataqueue.CAPACITY (on page 11-111)
dataqueue.clear() (on page 11-112)
dataqueue.count (on page 11-113)
dataqueue.next() (on page 11-114)
Digital I/O
The digital I/O port of the instrument can control external circuitry (such as a component handler for
binning operations).
The I/O port has 14 lines. Each line can be at TTL logic state 1 (high) or 0 (low). See the pinout
diagram in Digital I/O port (on page 3-25, on page 2-28) for additional information.
There are commands to read and write to each individual bit, and commands to read and write to the
entire port.
digio.readbit() (on page 11-115)
digio.readport() (on page 11-116)
digio.trigger[N].assert() (on page 11-116)
digio.trigger[N].clear() (on page 11-117)
digio.trigger[N].EVENT_ID (on page 11-117)
digio.trigger[N].mode (on page 11-118)
digio.trigger[N].overrun (on page 11-119)
digio.trigger[N].pulsewidth (on page 11-120)
digio.trigger[N].release() (on page 11-121)
digio.trigger[N].reset() (on page 11-121)
digio.trigger[N].stimulus (on page 11-122)
digio.trigger[N].wait() (on page 11-124)
digio.writebit() (on page 11-124)
digio.writeport() (on page 11-125)
digio.writeprotect (on page 11-126)

Table of Contents

Other manuals for Keithley 3700 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Keithley 3700 Series and is the answer not in the manual?

Keithley 3700 Series Specifications

General IconGeneral
BrandKeithley
Model3700 Series
CategoryMultimeter
LanguageEnglish

Related product manuals