9 - 43
9 Setting Up Slave Terminals
NX-series EtherCAT Coupler Unit User’s Manual (W519)
9-6 Precautions in Changing the Unit Configuration
9
9-6-3 Using Settings from NX Units on Other Slave Termi-
nals
To mount and use NX Units that were set for one Slave Terminal under a different EtherCAT Coupler
Unit, you must export and import NX Unit settings.
To use the NX Unit settings on a different Slave Terminal, you must export the NX Unit settings from the
Unit configuration of the set Slave Terminal and then import the settings to the Unit configuration of the
newly mounted Slave Terminal.
• Refer to 9-2-7 Sysmac Studio Functions Used as Required on page 9-25 for information on
exporting and importing NX Unit settings.
• Some of the NX Unit settings are saved in the EtherCAT Coupler Unit. Therefore, even if you
upload the NX Unit settings to an NX Unit that was set on a different Slave Terminal, the orig-
inal NX Unit settings are not correctly applied to the newly mounted Slave Terminal.
9-6-3 Using Settings from NX Units on Other Slave Terminals