11 EtherCAT Coupler Unit Functions
11 - 24
NX-series EtherCAT Coupler Unit User’s Manual (W519)
11-8 Changing Event Levels
This section describes changing event levels for the EtherCAT Slave Terminals.
You can change the event levels that are assigned to each Controller event.
Levels are set for each event in each Unit. If the same event code occurs in more than one Unit, you
can set a different event level for each Unit.
EtherCAT Coupler Unit
The EtherCAT Coupler Unit does not have events for which you can change the event level.
NX Units
Refer to Error Event Codes and Troubleshooting in the Troubleshooting section of the manual for the
NX Unit for the events for which you can change the event level in each NX Unit.
Changes to the event levels take effect only after they are downloaded and the Unit power supply is
cycled or the Units are restarted.
Additional Information
Changing the Event Levels for Current Errors
The event levels of current errors do not change when the event level settings are changed and
downloaded. You must restart the EtherCAT Coupler Unit or cycle the Unit power supply to
enable the changes.
11-8-1 Introduction
11-8-2 Details on Changing Event Levels
Unit of Event Level Settings
Events with Changeable Levels
When Changes Take Effect