3-6
3
îš‹ Drive Mode
The Drive mode is the mode in which the Inverter can be operated. All monitor parameters (U1-) as well
as fault information and the fault history can be displayed in this mode
When b1-01 (Reference selection) is set to 0, the frequency can be changed from the frequency setting display
using the Increment, Decrement, and Shift/RESET keys. The parameter will be written and the display returns
to the Monitor display.
Example Operations
Example key operations in drive mode are shown in the following figure.
Fig 3.4 Operations in Drive Mode
Frequency Ref
-DRIVE-
U1-02=50.00Hz
U1-03=10.05A
** Main Menu **
-DRIVE-
Operation
** Main Menu **
-QUICK-
Quick Setting
** Main Menu **
-ADV-
Programming
** Main Menu **
-VERIFY-
Modified Consts
** Main Menu **
-A.TUNE-
Auto-Tuning
U1- 01=50.00Hz
Monitor
-DRIVE-
U1-02=50.00Hz
U1-03=10.05A
U1 - 01=50.00Hz
Frequency Ref
-DRIVE-
U1-02=50.00Hz
U1-03=10.05A
U1- 01=50.00Hz
Frequency Ref
-DRIVE-
U1 - 01= 050.00Hz
Monitor Display Frequency Setting DisplayMode Selection
Display
Display at Startup
Fault Trace
-DRIVE-
U2-02= OV
U2-03=50.00Hz
U2 - 01=OC
Fault History
-DRIVE-
U3-02= OV
U3-03= OH
U3 -01= OC
Output Freq
-DRIVE-
U1-04= 2
U1-03=10.05A
U1- 02=50.00Hz
FAN Elapsed Time
-DRIVE-
U1-01=50.00Hz
U1-02=50.00Hz
U1- 40 = 10H
1 2
1 2
Last Fault
-DRIVE-
U3-02=OV
U3-03=OH
U3 - 01 = OC
Fault Message 2
-DRIVE-
U3-03= OH
U3-04= UV
U3 - 02 = OV
5 5
5 5
A B
A B
Current Fault
-DRIVE-
U2-02=OV
U2-03=50.00Hz
U2 - 01 = OC
Last Fault
-DRIVE-
U3-03=50.00Hz
U3-04=50.00Hz
U2 - 02 = OV
3 4
3 4
U2 - 01= OC
U2 - 02= OV
Over Current
DC Bus Overvolt
U3 - 01= OC
Over Current
U3 - 02= OV
DC Bus Overvolt
The fault name will be
displayed if the DATA/ENTER
Key is pressed while a constant
is being displayed for which a
fault code is being displayed.
Rdy
Rdy
Rdy
Rdy
Rdy
Rdy
Rdy
Rdy
Rdy Rdy
Rdy
Rdy
The Frequency Setting
Display will not be
displayed when using an
analog reference.
Monitor
-DRIVE-
U1-04= 2
U1-03=10.05A
U1 - 02=50.00Hz
Rdy
Monitor
-DRIVE-
U1-01=50.00Hz
U1-02=50.00Hz
U1 -40 = 10H
Rdy
Rdy
Rdy
Rdy
Fault Trace
-DRIVE-
U3-03=50.00Hz
U3-04=50.00Hz
U2 -02 = OV
Rdy
Fault Message 2
-DRIVE-
U3-03= OH
U3-04= UV
U3 -02= OV
Rdy
MENU
RESET
ESC
MENU
ESC
ESC
MENU
MENU
MENU
RESET
RESET
RESET
RESET
RESET
RESET
ESC
ESC
ESC ESC
ESC ESC
ESC ESC
ESC ESC
(0.00 ~ 50.00)
" 00.00Hz "

Table of Contents

Other manuals for Omron VARISPEED F7

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron VARISPEED F7 and is the answer not in the manual?

Omron VARISPEED F7 Specifications

General IconGeneral
BrandOmron
ModelVARISPEED F7
CategoryInverter
LanguageEnglish

Related product manuals