R8C/20 Group, R8C/21 Group 16. Clock Synchronous Serial Interface
Rev.2.00 Aug 27, 2008 Page 285 of 458
REJ09B0250-0200
Figure 16.2 SSCRH Register
SS Control Register H
Symbol Address After Reset
SSCRH
00B8h 00h
Bit Symbol Bit Name Function RW
NOTES:
1.
2.
3.
The SSCK pin functions as the transfer clock output pin w hen the MSS bit is set to 1 (operates as master device).
The MSS bit is set to 0 (operates as slave device) w hen the CE bit in the SSSR register is set to 1 (conflict error
occurs).
RSSTP
Receive single stop bit
(3)
0 : Maintains receive operation after
receiving 1-byte data
1 : Completes receive operation after
receiving 1-byte data
RW
—
(b7)
Nothing is assigned. If necessary, set to 0.
When read, the content is 0.
The set clock is used w hen the internal clock is selected.
—
Master/slave device select bit
(2)
0 : Operates as slave device
1 : Operates as master device
RWMSS
—
(b4-b3)
—
Nothing is assigned. If necessary, set to 0.
When read, the content is 0.
CKS1
CKS2
Transfer clock rate select bit
(1)
b2 b1 b0
0 0 0 : f1/256
0 0 1 : f1/128
0 1 0 : f1/64
0 1 1 : f1/32
1 0 0 : f1/16
1 0 1 : f1/8
1 1 0 : f1/4
1 1 1 : Do not set
CKS0
RW
RW
RW
The RSSTP bit is disabled w hen the MSS bit is set to 0 (operates as slave device).
b7 b6 b5 b4 b3 b2 b1 b0

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Renesas R8C/20 and is the answer not in the manual?

Renesas R8C/20 Specifications

General IconGeneral
BrandRenesas
ModelR8C/20
CategoryControl Unit
LanguageEnglish

Related product manuals