R8C/20 Group, R8C/21 Group 22. Notes on On-Chip Debugger
Rev.2.00 Aug 27, 2008 Page 452 of 458
REJ09B0250-0200
22. Notes on On-Chip Debugger
When using the on-chip debugger to develop the R8C/20 and R8C/21 Groups program and debug, pay the following
attention.
(1) Do not access the related UART1 registers.
(2) Some of the user flash memory and RAM areas are used by the on-ship debugger. These areas cannot be
accessed by the user.
Refer to the on-chip debugger manual for which areas are used.
(3) Do not set the address match interrupt (the registers of AIER, RMAD0, RMAD1 and the fixed vector tables)
in a user system.
(4) Do not use the BRK instruction in a user system.
Connecting and using the on-chip debugger has some peculiar restrictions. Refer to each on-chip debugger manual for
on-chip debugger details.