Page #716 background imageLoading...
Page #716 background image
Backing up and restoring data
4.3 Operating the service PC or the PG on the network
PCU-Basesoftware (IM8)
76 Commissioning Manual, 03/2009, 6FC5397-1DP10-4BA0
4. Select "Permissions" and activate the "Change" square for all the users in the "Allow"
column so that files can be saved in this directory (e.g. the ghost image).
Procedure on the PCU 50.3
The following steps must be carried out on the PCU:
1. Start the ServiceCenter with "Start Backup/Restore console".
2. Maintain the pre-setting of the "Network Options" on the PCU:
IP address of PCU: 192.168.214.241 with subnet screen form 255.255.255.0
IP address of PG/PC: 192.168.214.250 with subnet screen form 255.255.255.0
1. In the ServiceCenter, select the service task "Backup/Restore a Disk Image".
2. Establish a network connection to the released directory, e.g. \\SIEMENS-
ABC4711\PCU_Backup.
3. Restore the hard disk of the PCU using the ghost image.
Note
If the transfer is interrupted during the "Restore" process, no consistent system is
available on the hard disk, i.e. the "Restore" process cannot be repeated because the
PCU no longer boots up.
In this event, the "Emergency Boot System" on the USB memory store is used.
See also
How to backup and restore the hard disk (Page 67)
How to create a service system for PCU (Page 61)

Table of Contents

Other manuals for Siemens SINUMERIK

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINUMERIK and is the answer not in the manual?

Siemens SINUMERIK Specifications

General IconGeneral
BrandSiemens
ModelSINUMERIK
CategoryControl Unit
LanguageEnglish

Related product manuals