SIRIUS 3RR2 current monitoring relays
8.10 Technical data
SIRIUS Innovations
System Manual, 01/2011, A8E56203870002-03
733
8.10 Technical data
8.10.1 Performance features of current monitoring relays
Table 8- 13 Performance features of 3RR2 current monitoring relays
Analog setting current monitoring relays Digital setting current monitoring relays
Functions/Parameters
3RR2141-.A.30 3RR2142-.A.30 3RR2241-.F.30 3RR2242-.F.30
Rated current 1.6 to 16 A 4 to 40 A 1.6 to 16 A 4 to 40 A
Line system
configuration
AC 50/60 Hz AC 50/60 Hz AC 20 to 400 Hz AC 20 to 400 Hz
Supply voltage U
s
ï‚· -.AA30: 24 V AC/DC
ï‚· -.AW30: 24 to 240 V AC/DC
ï‚· -.FA30: 24 V AC/DC
ï‚· -.FW30: 24 to 240 V AC/DC
Monitoring for current
overshoots and/or
undershoots
2-phase 2-phase 3-phase 3-phase
Contacts 1 CO contact 1 CO contact 1 semiconductor
output/1 CO contact
1 semiconductor
output/1 CO contact
8.10.1.1 General data
Table 8- 14 General data for 3RR2 current monitoring relays
Feature Benefit 3RR21 Basic,
analog setting
3RR22 Standard,
digital setting
Sizes
ï‚· Are matched to the dimensions, connections and technical
features of the other devices in the SIRIUS modular system
ï‚· Permit the mounting of slim-line and compact load feeders
in widths of 45 mm (S00 and S0)
ï‚· Make configuration easier
S00, S0 S00, S0
Current range
ï‚· Are matched to the other devices in the SIRIUS modular
system
ï‚· Just 1 option per size with a wide setting range makes
configuration easy
S00: 1.6 to 16 A
S0: 4.0 to 40 A
S00: 1.6 to 16 A
S0: 4.0 to 40 A