383
Creating a Cross-Point
Assign Table
You can create up to 14 other tables (Table1 to Table14)
as cross-point assign tables.
You can set logical V/K pairs in a cross-point assign
ta
ble.
Creating Tables 1 to 14
You can assign logical V/K pairs configured in the logical
V/K pair name table to cross-point button numbers.
1
Open the Home > Setup > Xpt Assign > Table Button
Assign menu (19102.31).
2
Display the target table to set.
Select a tab to change the table (Table1 to Table14) to
di
splay.
3
Select the target button number to set.
To select and set multiple button numbers, place a
ch
eck mark beside the target button numbers to set.
To select and set all button numbers, place a check
mar
k in the Select All checkbox.
4
Press the [Edit] button.
The [Select Logical V/K Pair] window appears.
5
Set the button for the logical V/K pair to assign to the
on state.
Select a tab to change the logical V/K pair to display.
6
Press [OK].
To inhibit operation
Select the target button number and set the [Inhibit]
swi
tch to the on state.
To delete a button number setting
Select the target button number to delete and press the
[
Delete] button.
The settings for all the button numbers not deleted move
up
in sequence.
To insert a button number setting
Select the button number at the insertion position and
p
ress [Insert].
A button number is inserted and the settings of all other
bu
ttons are shifted by one.
To return to the initial settings
Press the [Default Recall] button, check the message, then
press [OK]
.
Setting the Shift Button
Setting the [SHIFT] button operation
mode
You can set the operation mode of the [SHIFT] button
assigned to the right edge of the cross-point button row in
the cross-point control block/AUX bus control block
(AUX bus operation mode).
You can set it for each cross-point assign table.
The [SHIFT] button operation mode is set by the settings
of
the cross-point assign table of the switcher bank,
regardless of the buses assigned to the cross-point button
rows.
1
Open the Home > Setup > Xpt Assign > Shift Mode
menu (19102.41).
2
Select the target table to set.
To select and set multiple tables, place a check mark
be
side the target tables to set.
To select and set all tables, place a check mark in the
Sel
ect All checkbox.
3
Press the [Xpt Shift Mode] button and select an
operation mode from the pull-down list.
Hold: F
unctions as a shift button, and the shifted state
of a cross-point button is enabled while the button
is pressed.
Lock: F
unctions as a shift button, and pressing a
button toggles between the shifted and unshifted
states of the cross-point.
Off:
Functions as a cross-point button.
Setting the [SHIFT ALL] button operation
mode
You can set the operation mode of the [SHIFT ALL]
button assigned to the cross-point pad/function button
section of the cross-point control block.
The setting is common to all cross-point assign tables.
1
Open the Home > Setup > Xpt Assign > Shift Mode
menu (19102.41).
2
Set the operation mode using the [Shift All Hold]
button.
Note