Troubleshooting
Symptom Matrix
The Symptom Matrix (Table
6-5)
is
an
aid
in
determining which modules to
troubleshoot. There
is
no separate troubleshooting procedure for the power
supply, since each module troubleshooting procedure includes checks of
the power
supply. The CRT
is
checked
in
the display control and display
driver troubleshooting procedures.
The.
indicates the troubleshooting procedure most likely to locate the
failed module. The 0 indicates additional troubleshooting procedures that
may
help located the failed module.
Table 6-5:
Symptom Matrix
Symptom Processor
Analog Display
Front Display
Driver Panel
Control
Display Problems
No
display at all
0
0 0 0
Traces or readout, but not both
0
0
0
Abnormal readout
0
Abnormal traces
0
Abnormal traces and readout
0 0
Power-on diagnostics indicates a failure
0
Self-calibration does not pass
0
Volts/Div and Sec/Div controls
One control works but not both
0
0
Neither control works
0 0
No control of Volts/Div or vertical position of a
0
single channel
No control of Volts/Div or vertical position of
0
0
any channels
Intensity Control Problems
No control of readout and trace intensity
0
0
Control of readout
or
trace intensity but
0
not both
Focus Problems
No control of focus
0
Unable to focus properly
0
No control of trace rotation
No control of scale illumination
6-40
Maintenance
Scan by Zenith

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Tektronix TAS 475 and is the answer not in the manual?

Tektronix TAS 475 Specifications

General IconGeneral
BrandTektronix
ModelTAS 475
CategoryTest Equipment
LanguageEnglish

Related product manuals