Warranted Characteristics
Table 1-16: Warranted Characteristics - Power Requirements
Name
Source Voltage and Frequency
Power Consumption
Description
90-132
VACRMS
continuous range for 48 through 440 Hz.
180-250
VACRMS
continuous range for 48 through 440
Hz.
:5:85
watts (150
VA).
Table 1-17: Warranted Characteristics - Environmental and Safety
Name
Third Party Certifications
Temperature: Operating and
Nonoperating
Humidity: Operating and Nonoperating
Altitude: Operating and Nonoperating
Random Vibration: Nonoperating
Random Vibration: Operating
Emissions
Electrostatic Discharge Susceptibility
TAS 475 and TAS 485 Service Manual
Description
This product shall conform to and be certified where appropriate
according
to
the following requirements:
Certification
Underwriter's Laboratories
(UL)
Listed
or
Recognized
Component,
Electrical and
Electronic Measuring and Testing
Equipment UL 1244.
Canadian Standards
CSA
Association (CSA)
Self-Certification International
Electro-Technical Commission
(lEG)
Operating:
-10
0
C
to
+55
0
C.
Nonoperating:
-51
0
C to +71
0
C.
Category Certified Electronic
Development and
Test
Equipment, CSA 22.2 no. 231.
Self-certified by Tektronix
to
comply with
IEC
348
recommendation.
To
95% relative humidity at or below
+40
0
C to 75% relative
humidity form
+41
0
C to
+55
0
C.
A more sever test than stated
in
MIL-
T
-28800E,
para. 4.5.5.1.1.2.
Operating:
To
4572 m (15,000 ft.).
Nonoperating:
To
12192 m (40,000 ft.).
2.46
gRMS,
from 5
to
500
Hz,
10 minutes each axis.
0.31
gRMS,
from 5 to 500
Hz,
10 minutes each axis.
The instrument meets or exceeds
the
EMC requirements of the
following standards:
•
VFG
243.
• FCC Code of Federal Regulations, 47 CFR, Part 15, Subpart
B,
ClassA.
IEC
801-2.
1-15