FUEL SYSTEM
-
Injection Pump
FU-17
Retaining Nut
PIJ
Retaining Socket
*PIJ
Body Socket
2. (2L-T Austria)
ASSEMBLY AND ADJUSTING PI LOT INJECTION
(PIJ) ACTUATOR
(a)
Install the following parts to the holder body.
(1) Adjusting shim (for piston lift gap)
(2)
Stopper
(3)
Adjusting shim (for opening pressure)
(4) Pressure spring
(5) Pressure pin
(6) Distance piece
(7)
Accumulator assembly
NOTICE:
Do not mix up the shims in (1) and
(3)
above.
(b)
Using the PIJ body socket and PIJ retaining socket,
install the retaining nut.
Part No.
95096-10390 and 95096-10400 (NI PPONDENSO)
Torque:
675 kg-cm
(49
ft-lb, 66 N-m)
(c)
Place the PIJ actuator and magnet stand on top of the
surface place, insert the measure attachment in the
thread hole in the plug bolt, and set the dial gauge.
Part No. 95096-10420 (NI PPONDENSO)
(d)
Set the dial indicator scale to 0 mm (0 in.) on top of
the measure attachment.
(e)
Press down on the edges of the measure attachment
and measure the piston lift gap.
Piston lift gap:
0.175
-
0.475 mm
(0.00689
-
0.01870 in.)
If the piston lift gap
is
not as specified, change the shim.
(See page
F