7.3 The Coefficient Configuration File
The Coeff_FXS.dat and Coeff_FXO.dat files are used to provide best termination and
transmission quality adaptation for different line types for MP-1xx/FXS and MP-10x/FXO
gateways respectively. This adaptation is performed by modifying the telephony interface
characteristics (such as DC and AC impedance, feeding current and ringing voltage).
The coeff.dat configuration file is produced specifically for each market after comprehensive
performance analysis and testing, and can be modified on request. The current file supports US
line type of 600 ohm AC impedance and (for FXS) 40 V RMS ringing voltage for REN = 2.
To load the coeff.dat file to the MP-1xx use the Embedded Web Server (refer to Section
5.9.4 on
page 122) or alternatively specify the FXS/FXO coeff.dat file name in the gateway’s ini file (refer
to Section
5.11.2.1 on page 138).
The Coeff.dat file consists of a set of parameters for the signal processor of the loop interface
devices. This parameter set provides control of the following AC and DC interface parameters:
DC (battery) feed characteristics
AC impedance matching
Transmit gain
Receive gain
Hybrid balance
Frequency response in transmit and receive direction
Hook thresholds
Ringing generation and detection parameters
This means, for example, that changing impedance matching or hybrid balance doesn’t require
hardware modifications, so that a single device is able to meet requirements for different markets.
The digital design of the filters and gain stages also ensures high reliability, no drifts (over
temperature or time) and simple variations between different line types.
In future software releases, it is to be expanded to consist of different sets of line parameters,
which can be selected in the ini file, for each port.

Table of Contents

Other manuals for AudioCodes MP-100

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the AudioCodes MP-100 and is the answer not in the manual?

AudioCodes MP-100 Specifications

General IconGeneral
BrandAudioCodes
ModelMP-100
CategoryGateway
LanguageEnglish

Related product manuals