MP-1xx SIP
MP-1xx SIP User’s Manual 232 Document #: LTRT-65404
G.1.4 Other Traps
The following are provided as SNMP traps and are not alarms.
Table G-8: coldStart Trap
Trap Name:
coldStart
OID:
1.3.6.1.6.3.1.1.5.1
MIB
SNMPv2-MIB
Note: This is a trap from the standard SNMP MIB.
Table G-9: authenticationFailure Trap
Trap Name:
authenticationFailure
OID:
1.3.6.1.6.3.1.1.5.5
MIB
SNMPv2-MIB
Table G-10: acBoardEvBoardStarted Trap
Trap Name:
acBoardEvBoardStarted
OID:
1.3.6.1.4.1.5003.9.10.1.21.2.0.4
MIB
AcBoard
Severity
cleared
Event Type:
equipmentAlarm
Probable Cause:
Other(0)
Alarm Text:
Initialization Ended
Note: This is the AudioCodes Enterprise application cold start trap.
G.1.5 Trap Varbinds
Each trap described above provides the following fields (known as ‘varbinds’). Refer to the
AcBoard MIB for additional details on these varbinds.
• acBoardTrapGlobalsName
• acBoardTrapGlobalsTextualDescription
• acBoardTrapGlobalsSource
• acBoardTrapGlobalsSeverity
• acBoardTrapGlobalsUniqID
• acBoardTrapGlobalsType
• acBoardTrapGlobalsProbableCause
• acBoardTrapGlobalsAdditionalInfo1
• acBoardTrapGlobalsAdditionalInfo2
• acBoardTrapGlobalsAdditionalInfo3
Note that ‘acBoardTrapGlobalsName’ is actually a number. The value of this varbind is ‘X’ minus
1, where ‘X’ is the last number in the trap’s OID. For example, the ‘name’ of
‘acBoardEthernetLinkAlarm’ is ‘9’. The OID for ‘acBoardEthernetLinkAlarm’ is 1.3.6.1.4.1.5003.
9.10.1.21.2.0.10.