MP-1xx SIP
MP-1xx SIP User’s Manual 182 Document #: LTRT-65404
The enterprise acBoardEvBoardStarted which is generated at the end of system
initialization. This is more of an ‘application-level’ cold start sent after the entire initializing
process is complete and all the modules are ready.
11.4 Third-Party Performance Monitoring
Measurements
Performance measurements are available for a third-party performance monitoring system
through an SNMP interface. These measurements can be polled at scheduled intervals by an
external poller or utility in a media server or other off-device system.
The device provides two types of performance measurements:
1. Gauges: Gauges represent the current state of activities on the device. Gauges, unlike
counters, can decrease in value, and like counters, can increase. The value of a gauge is the
current value or a snapshot of the current activity on the device.
2. Counters: Counters always increase in value and are cumulative. Counters, unlike gauges,
never decrease in value unless the off-device system is reset, the counters are then zeroed.
Performance measurements are provided by three proprietary MIBs (acPerfMediaGateway,
acPerfMediaServices and acPerfH323SIPGateway). The first MIB is a generic-type of
performance measurements MIB available on all MP-1xx and related devices. The second is
specific to the media server, and the third is for H.323/SIP media gateways.
The generic performance measurements MIB covers:
Control protocol
RTP stream
System packets statistics
Performance measurement enterprise MIB supports statistics which apply to the
Proxy/Gatekeeper routing tables.
11.5 Supported MIBs
The MP-1xx contains an embedded SNMP Agent supporting the following MIBs:
Standard MIB (MIB-II) - The various SNMP values in the standard MIB are defined in RFC
1213. The standard MIB includes various objects to measure and monitor IP activity, TCP
activity, UDP activity, IP routes, TCP connections, interfaces and general system indicators.
RTP MIB - The RTP MIB is supported in conformance with the IETF RFC 2959. It contains
objects relevant to the RTP streams generated and terminated by the device and to RTCP
information related to these streams.
NOTIFICATION-LOG-MIB - This standard MIB (RFC 3014 - iso.org.dod.internet.mgmt.mib-
2) is supported as part of our implementation of carrier grade alarms.
ALARM-MIB - This is an IETF proposed MIB also supported as part of our implementation of
carrier grade alarms. This MIB is still not standard and is therefore under the
audioCodes.acExperimental branch.
SNMP-TARGET-MIB - This MIB is partially supported (RFC 2273). It allows for the
configuration of trap destinations and trusted managers only.
SNMP Research International Enterprise MIBs – MP-1xx supports two SNMP Research
International MIBs: SR-COMMUNITY-MIB and TGT-ADDRESS-MASK-MIB. These MIBs are
used in the configuration of SNMPv2c community strings and trusted managers.
In addition to the standard MIBs, the complete series contains several proprietary MIBs:

Table of Contents

Other manuals for AudioCodes MP-100

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the AudioCodes MP-100 and is the answer not in the manual?

AudioCodes MP-100 Specifications

General IconGeneral
BrandAudioCodes
ModelMP-100
CategoryGateway
LanguageEnglish

Related product manuals