Appendix 8 Managing the Switch Hardware
Information About Module Temperature
DETAILED STEPS
Information About Module Temperature
This section includes the following topics:
• Overview of Module Temperatures, page 8-24
• Displaying the Module Temperature, page 8-25
Overview of Module Temperatures
Built-in, automatic sensors are provided in all switches in the Cisco Nexus 7000 Series to monitor your
switch at all times.
Each module (supervisor, I/O, and fabric) has temperature sensors with two thresholds:
• Minor temperature threshold—When a minor threshold is exceeded, a minor alarm occurs and the
following actions occur for all four sensors:
–
System messages are displayed.
–
Call Home alerts are sent (if configured).
–
SNMP notifications are sent (if configured).
• Major temperature threshold—When a major threshold is exceeded, a major alarm occurs and the
following actions occur:
–
For sensors 1, 3, and 4 (outlet and onboard sensors), the following actions occur:
System messages are displayed.
Call Home alerts are sent (if configured).
SNMP notifications are sent (if configured).
–
For sensor 2 (intake sensor), the following actions occur:
If the threshold is exceeded in a switching module, only that module is shut down.
Command Purpose
Step 1
config t
Example:
switch# config t
switch(config)#
Starts the global configuration mode.
Step 2
poweroff module slot_number
Example:
switch(config)# poweroff module 1
switch(config)#
Powers off the specified I/O module in the switch.
no poweroff module slot_number
Example:
switch(config)# no poweroff module 1
switch(config)#