EasyManuals Logo

Cisco Nexus 7000 User Manual

Cisco Nexus 7000
508 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #301 background imageLoading...
Page #301 background image
10-43
Cisco Nexus 7000 Series Hardware Installation and Reference Guide
OL-23069-07
Chapter 10 Installing or Replacing Components
Installing a NAM Module
Step 1 Use a browser to go to http://software.cisco.com/download/navigator.html.
The Software Download page opens.
Step 2 Choose Cloud and Systems Management > Network Analysis Module (NAM) Products > Cisco
Prime Network Analysis Module Software > Cisco Prime Network Analysis Module Software 6.2
(or later verssion). A list of software files appears.
Step 3 Click the Download button for the software file name beginning with nam-nx1. The filename is
nam-nx1.x-x-x.bin.gz (where x-x-x is the NAM software release number).
Step 4 Using the NAM CLI, enter the upgrade command to specify the user, password, server,path to the file,
and installation file name. For example, for the admin user, “secret” password, server IP address
10.10.10.10, archive/nam_software path, and nam-nx1.6.0.1.bin.gz installation file, you would use the
upgrade command as follows:
upgrade ftp://admin:secret!10.10.10.10//archive/nam_software/nam-nx1.6.0.1.bin.gz
Configuring the NAM
To configure the NAM software, you must do all of the following:
Configure the VLAN management port from the switch (see the “Configuring a VLAN Management
Port for the NAM” section on page 10-43).
Configure the SPAN session from the switch (see the “Configuring a SPAN Session for a Data Port”
section on page 10-44).
Set up the NAM network configuration for the NAM (see the “Specifying the NAM IP Configuration
and Enabling the Web Server” section on page 10-46).
Configuring a VLAN Management Port for the NAM
Using the virtual device context (VDC) that the NAM belongs to, you must configure a VLAN for NAM
management traffic, and you must assign that VLAN to the NAM management port.
To configure and assign a VLAN management port, follow these steps:
Step 1 Verify that the NAM is active.
switch# show service nam summary
Service Service
Name Type Interface Module State Version
---------------- ----------- -------------- --------- --------- ---------------
NAM7 NAM Po4096, Po4095 7 active 6.0
Step 2 Allocate the NAM interfaces to the VDC as follows:
If you are using the default VDC configuration, the NAM interfaces should be allocated to the
default VDC automatically. Verify that allocation.
switch(config)# show run vdc
!Command: show running-config vdc
!Time: Wed May 29 18:47:17 2013
version 6.2(2)
no system admin-vdc
vdc N7K-8 id 1

Table of Contents

Other manuals for Cisco Nexus 7000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco Nexus 7000 and is the answer not in the manual?

Cisco Nexus 7000 Specifications

General IconGeneral
Chassis TypeModular
Product TypeSwitch
Power SupplyAC or DC
CoolingRedundant, hot-swappable fan trays
ManagementCLI, SNMP
Form FactorModular chassis
Interfaces/PortsVaries by module
Product SeriesNexus 7000
Port DensityVaries by module
RedundancyPower supply, fan, supervisor engine
Management InterfacesConsole, Ethernet
Security FeaturesACLs, port security
Virtualization SupportVRF
Operating Temperature0 to 40°C (32 to 104°F)
Storage Temperature-40°F to 158°F (-40°C to 70°C)
Humidity5% to 95% non-condensing