July 2010 30 – 605
MP3440.0-7 k factor for spindle orientation for gear ranges 1 to 8
Input: 0.1 to 10 [(1000°/ min) /°]
PLC
RUN
MP3450.0-7 Number of spindle position-encoder revolutions for gear ranges 1 to 8
Input: 0 to 65 535
0: No transmission
PLC
RUN
340 490-05
MP3451.0-7 Number of spindle revolutions for gear ranges 1 to 8
Input: 0 to 65 535
0: No transmission
PLC
RUN
340 490-05
MP3510.0-7 Rated speed for the gear ranges 1 to 8
Input: 0 to 99 999.999 [rpm]
PLC
RUN
MP3515.0-7 Maximum spindle speed for gear ranges 1 to 8
Input: 0 to 99 999.999 [rpm]
PLC
RUN
MP3520.0 Speed activation through marker M4011
Input: 0 to 99 999.999 [rpm]
PLC
RUN
MP3520.1 Spindle speed for oriented stop
Input: 0 to 99 999.999 [rpm]
MP3530 Increased spindle power for roughing
Input: 0 = Not active
1 = Increased spindle power for roughing
340 490-03
MP3540 As of CC424(B): Permissible lower spindle speed limit
Input: 0.001 to 0.999
0: Monitoring not active
340 490-05
MP3542 As of CC 424(B): Minimum spindle speed as of which the monitoring in MP3540
becomes active
Input: 0.001 to 0.999
0: Monitoring not active
340 490-05
MP3550 As of CC424(B): Delay of EMERGENCY STOP reaction of spindles
Input: 0.001 to 0.100 [s]
0: Delay not active
340 490-05
MP Function and input SW version
and
behavior