MAINTENANCE
7-53
Check Fuel Level
--- every 8 hours (daily)
d
CAUTION: Handle fuel carefully. Shut the engine off
before fueling. Do not smoke while you fill the fuel
tank or work on fuel system.
1. Parkthemachinefollowingthesameproceduresas
describedonpage7-6forpreparationforinspectionand
maintenance.
2. Checkfuellevelgauge(3)andfuelgauge(1)ofthe
monitorpanel.Whennecessarytoaddfuel,removecap
(2) and refill fuel.
IMPORTANT: Keep all dirt, dust, water and other foreign
materials out of the fuel system when refilling fuel.
3. Toavoidcondensation,fillthetankattheendof
eachday’soperation.Takecarenottospillfuelonthe
machine or ground.
Model TankCapacity
ZX30U-5N,35U-5N 42L(11.1USgal)
ZX50U-5N 70L(18.5USgal)
ZX60USB-5N 120L(31.7USgal)
4. Afterrefillingfuel,installcap(2).Closetankcover(4)and
besuretolockcover(4)topreventvandalism.
3
2
MADB-07-041
4
1
MADH-01-009