OPERATOR'S STATION
1-25
Muffler Filter (ZX50U-5N, 60USB-5N)
Muffler Filter Condition Display
MufflerFilterDisplay(1)displaystheconditionofthe
muffler filter.
Thismarkindicatesthattheexhausttemperatureis
high during the muffler filter regeneration. It lights
whileauto-regenerationisinprocess.
f
NOTE:
The auto-regeneration is performed at random times.
The auto-regeneration may start during operation of
the machine; you can continue to operate the machine.
Turning the pilot shut-off lever to LOCK position while
performing auto-regeneration may change the engine
sound, this is not a malfunction.
The engine sound may differ from normal sound during
auto-regeneration, which is not a malfunction.
Do not stop the engine during regeneration unless
absolutely necessary.
Regenerationmaynotbecompletedaccordingtothe
operating conditions of the machine. In this case, muffler
filter manual regeneration request will be displayed on
monitor (2). Immediately perform manual regeneration
following the procedure.
Thismarkindicatesthatthemufflerfilter
regenerationisinhibited.Regenerationwillnotbe
performedwhilethismarkislit.However,auto-
regeneration may be performed depending on the
workingconditions,whichisnotamalfunction.
IMPORTANT: Set the muffler filter regeneration to
inhibited while operating the machine in a flammable
environment. (Refer to 1-31)
1
2
MADH-01-066