114 Call Home Configuration
Adding a data capture configuration
To add a data capture configuration to the Tech_Support_Center profile, enter the capture add
command, as shown in the following example. If the Tech_Support_Center profile does not exist, you must
create it using the profile create command.
SN6000 FC Switch #> admin start
SN6000 FC Switch (admin) #> callhome edit
SN6000 FC Switch (admin-callhome) #> capture add
A list of attributes with formatting and default values will follow.
Enter a value or simply press the ENTER key to accept the default value.
If you wish to terminate this process before reaching the end of the list
press 'q' or 'Q' and the ENTER key to do so.
Value (press ENTER to accept the default, 'q' to quit):
TimeOfDay (HH:MM) [02:00]
DayOfWeek (Sun,Mon,Tue,Wed,Thu,Fri,Sat) [Sat ]
Interval (decimal value, 1-26 weeks) [1 ]
A capture entry has been added to profile Tech_Support_Center.
This configuration must be saved with the 'callhome save' command
before it can take effect, or to discard this configuration
use the 'callhome cancel' command.
Modifying a data capture configuration
to modify a data capture configuration in the Tech_Support_Center profile, enter the capture edit
command, as shown in the following example:
SN6000 FC Switch #> admin start
SN6000 FC Switch (admin) #> callhome edit
SN6000 FC Switch (admin-callhome) #> capture edit
Capture Entries for Profile: Tech_Support_Center
Index TimeOfDay DayOfWeek Interval
----- --------- --------- --------
1 02:00 Sat 1 (weeks)
Please select a capture entry from the list above ('q' to quit): 1
A list of attributes with formatting and current values will follow.
Enter a value or simply press the ENTER key to accept the current value.
If you wish to terminate this process before reaching the end of the list
press 'q' or 'Q' and the ENTER key to do so.
Value (press ENTER to accept the default, 'q' to quit):
TimeOfDay (HH:MM) [02:00]
DayOfWeek (Sun,Mon,Tue,Wed,Thu,Fri,Sat) [Sat ]
Interval (decimal value, 1-26 weeks) [1 ]
The selected capture entry has been edited for profile Tech_Support_Center.
This configuration must be saved with the 'callhome save' command
before it can take effect, or to discard this configuration
use the 'callhome cancel' command.

Table of Contents

Other manuals for HP StorageWorks SN6000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP StorageWorks SN6000 and is the answer not in the manual?

HP StorageWorks SN6000 Specifications

General IconGeneral
BrandHP
ModelStorageWorks SN6000
CategorySwitch
LanguageEnglish

Related product manuals