94 Device Security Configuration
Adding members to a group
Adding a member to a group involves specifying a group, the member worldwide name, and the member
attributes. The member attributes define the authentication method, encryption method, secrets, and fabric
binding, depending on the group type.
• For ISL member attributes, see Table 8.
• For Port member attributes, see Table 9.
• For MS member attributes, see Table 10.
To add a member to a group, enter the group add command, as shown in the following example:
SN6000 FC Switch #> admin start
SN6000 FC Switch (admin) #> security edit
SN6000 FC Switch (admin-security) #> group add Group_1
A list of attributes with formatting and default values will follow
Enter a new value or simply press the ENTER key to accept the current value
with exception of the Group Member WWN field which is mandatory.
If you wish to terminate this process before reaching the end of the list
press 'q' or 'Q' and the ENTER key to do so.
Group Name Group_1
Group Type ISL
Member (WWN) [00:00:00:00:00:00:00:00]
10:00:00:c0:dd:00:90:a3
Authentication (None / Chap) [None ] chap
PrimaryHash (MD5 / SHA-1) [MD5 ]
PrimarySecret (32 hex or 16 ASCII char value) [ ] 0123456789abcdef
SecondaryHash (MD5 / SHA-1 / None) [None ]
SecondarySecret (40 hex or 20 ASCII char value) [ ]
Binding (domain ID 1-239, 0=None) [0 ]
Finished configuring attributes.
To discard this configuration use the security cancel command.
Modifying a group member
Modifying a group member involves changing the member attributes. The member attributes define the
authentication method, encryption methods, secrets, and fabric binding, depending on the group type.
• For ISL member attributes, see Table 8.
• For Port member attributes, see Table 9.
• For MS member attributes, see Table 10.
To change the attributes of a group member, enter the group edit command, as shown in the following
example:
SN6000 FC Switch #> admin start
SN6000 FC Switch (admin) #> security edit
SN6000 FC Switch (admin-security) #> group edit G1 10:00:00:c0:dd:00:90:a3
A list of attributes with formatting and current values will follow.
Enter a new value or simply press the ENTER key to accept the current value.

Table of Contents

Other manuals for HP StorageWorks SN6000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP StorageWorks SN6000 and is the answer not in the manual?

HP StorageWorks SN6000 Specifications

General IconGeneral
BrandHP
ModelStorageWorks SN6000
CategorySwitch
LanguageEnglish

Related product manuals