HP StorageWorks SN6000 Fibre Channel Switch Command Line Interface Guide 67
Testing a port
You can test a port using the test port command using online or offline tests. The following sections
describe the test types, displaying test results, and cancelling a test.
Online tests for ports
An online test is a non-disruptive test that exercises the port, transceiver, and device connections. The port
must be online and connected to a device. Online testing of TR_Ports is not allowed. The following is an
example of an online test:
SN6000 FC Switch #> admin start
SN6000 FC Switch (admin) #> test port 1 online
A list of attributes with formatting and current values will follow. Enter a new
value or simply press the ENTER key to accept the default value. If you wish to
terminate this process before reaching the end of the list press 'q' or 'Q' and
the ENTER key to do so.
LoopCount (decimal value, 1-4294967295) [429496729]
FrameSize (decimal value, 40-2148) [256 ]
DataPattern (32-bit hex value or 'Default') [Default ]
StopOnError (True / False) [True ]
LoopForever (True / False) [False ]
Do you want to start the test? (y/n) [n] y
The test has been started.
A notification with the test result(s) will appear
on the screen when the test has completed.
SN6000 FC Switch (admin) #>
Test for port 1 Passed.

Table of Contents

Other manuals for HP StorageWorks SN6000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP StorageWorks SN6000 and is the answer not in the manual?

HP StorageWorks SN6000 Specifications

General IconGeneral
BrandHP
ModelStorageWorks SN6000
CategorySwitch
LanguageEnglish

Related product manuals